To order: call 412-968-0100
Standard Medium Voltage Starter Products
Prepackaged Solid State Starters
mVrxe SerIeS

Highlights:
The Benshaw Medium Voltage Starter is a microprocessor controlled
solid state reduced voltage starter for three phase induction motors.
The starter provides a closed-loop current ramp for smooth stepless
motor acceleration. Supplied in a free standing enclosure.
Enclosures are available in NEMA 12 or NEMA 3R configurations. The
medium voltage enclosure consists of two distinct compartments.
The medium voltage or power pole section is located in the main
body of the enclosure, whereas the low voltage section containing the
control logic is located behind the door as an isolated compartment.
Each starter is supplied with a load break isolation switch, Class “R”
motor fuses, inline vacuum contactor, solid state power poles, and a
vacuum bypass contactor, which is used to bypass the SCR power
poles once the motor is up to full speed.
The logic control incorporates the MX
3
computer that has all the
circuitry required to drive the power semiconductors, which are
located in the power section.
MVRXE starters provide solid state reduced voltage starting for
normal operation and full voltage emergency back-up starting, with
complete electronic motor protection at the flip of a switch.
This unique redundant design is ideal for critical applications where
downtime is extremely disruptive and cannot be tolerated.
MX
3
solid state controls provide precise digital starting and stopping,
motor protection, metering, diagnostics and communications,
standard.
Key Advantages:
• NEMA 12, UL 347 listed
• 45 kV BIL
• Service entrance labeled (optional)
• Built-in self test (BIST) features for
“quick commissioning”
• Solid state reduced voltage
starting — normal operations
• 425 A load break
• Switch selectable emergency back-
up full voltage starter
• MX
3
-embedded digital control
• Fiber optic firing
• Advanced motor protection
• Advanced metering
• Power quality protection
• Diagnostics and ModBus RTU485
communications standard