103
Cin Span I/O 24
I/O: Cin Span
24 100.0%
7 - PARAMETER DESCRIPTION
LCD Display
Range 0.0 to 200.0% (Default 100%)
Description This parameter is used to alter the range of the input being received at terminal (Cin). For example, with a
0-20mA DC input, setting this parameter to a value of 50% alters the range to 0 to 10mA DC.
See also DRV 05 on page 78 & I/O 23, 25, 26
CinOffset I/O25
Cin Filter I/O 26
I/O: Cin Filter
26 15ms
I/O: Cin Oset
25 0.0%
LCD Display
Range 0.0 to 100.0% (Default 0.0%)
Description This parameter is used to alter the starting value of the input being received at terminal Cin. For example
with Cin Cong set to 4 to 20mA, setting this parameter to 50% alters the range to 12-20mA.
See also I/O 23, 24
LCD Display
Range 1 to 1000 ms (Default 15ms)
Description This parameter sets the low-pass lter time for the analog input signal received at terminal Cin. Longer
lter times better reduce noise disturbances but will also slow the signal response time.
See also I/O 23, 24, 25